Tóm tắt:
This study compared results of online circular contrast perimetry (OCCP) versus standard automated perimetry (SAP) in clinic, as well as clinic OCCP versus home OCCP in a normal Asian population. Healthy participants underwent a comprehensive ocular examination, retinal nerve fiber layer optical coherence tomography scan, and visual field tests performed in clinic, using OCCP and SAP. Within a week, participants were asked to repeat OCCP field test at home. 58 eyes of 29 healthy volunteers were selected. At the clinic, no difference between testing duration and fixation loss of SAP and OCCP was detected.