Online circular contrast perimetry: The normative database of an Asian population
Tác giả: Hoang Thanh Tung, Mai Quoc Tung, Pham Thi Dung, Nguyen Thi Xuan, Nguyen Duc Anh, Vu Thi Diu, Hoang Thi Hien, Simon Skalicky Franzco
Số trang:
P. 151-160
Số phát hành:
Volume 184 E15 - N 11
Kiểu tài liệu:
Tạp chí trong nước
Nơi lưu trữ:
03 Quang Trung
Mã phân loại:
610
Ngôn ngữ:
Tiếng Anh
Từ khóa:
Online circular contrast perimetry, normal, healthy
Chủ đề:
Ophthalmology
Tóm tắt:
This study compared results of online circular contrast perimetry (OCCP) versus standard automated perimetry (SAP) in clinic, as well as clinic OCCP versus home OCCP in a normal Asian population. Healthy participants underwent a comprehensive ocular examination, retinal nerve fiber layer optical coherence tomography scan, and visual field tests performed in clinic, using OCCP and SAP. Within a week, participants were asked to repeat OCCP field test at home. 58 eyes of 29 healthy volunteers were selected. At the clinic, no difference between testing duration and fixation loss of SAP and OCCP was detected.
Tạp chí liên quan
- Kích thước niệu quản trên cắt lớp vi tính và mối liên quan với các chỉ số nhân trắc
- Đặc điểm đa hình rs4244285 của gen CYP2C19 và một số yếu tố liên quan kết quả điều trị ở người bệnh trào ngược dạ dày thực quản
- Kết quả phẫu thuật đục thể thủy tinh sử dụng laser femtosecond tại Bệnh viện Mắt Trung ương (2017 – 2023)
- Diễn tiến độ thanh thải triglyceride huyết thanh và mối liên quan với biến chứng nội viện trong viêm tụy cấp do tăng triglyceride: Kết quả bước đầu từ nghiên cứu quan sát tiến cứu
- Kết quả điều trị đơn trị pembrolizumab ở bệnh nhân ung thư phổi không tế bào nhỏ có bộc lộ PD-L1 ≥ 50% tại Bệnh viện Phổi Trung ương