Online circular contrast perimetry: The normative database of an Asian population
Tác giả: Hoang Thanh Tung, Mai Quoc Tung, Pham Thi Dung, Nguyen Thi Xuan, Nguyen Duc Anh, Vu Thi Diu, Hoang Thi Hien, Simon Skalicky Franzco
Số trang:
P. 151-160
Số phát hành:
Volume 184 E15 - N 11
Kiểu tài liệu:
Tạp chí trong nước
Nơi lưu trữ:
03 Quang Trung
Mã phân loại:
610
Ngôn ngữ:
Tiếng Anh
Từ khóa:
Online circular contrast perimetry, normal, healthy
Chủ đề:
Ophthalmology
Tóm tắt:
This study compared results of online circular contrast perimetry (OCCP) versus standard automated perimetry (SAP) in clinic, as well as clinic OCCP versus home OCCP in a normal Asian population. Healthy participants underwent a comprehensive ocular examination, retinal nerve fiber layer optical coherence tomography scan, and visual field tests performed in clinic, using OCCP and SAP. Within a week, participants were asked to repeat OCCP field test at home. 58 eyes of 29 healthy volunteers were selected. At the clinic, no difference between testing duration and fixation loss of SAP and OCCP was detected.